110 research outputs found

    Novel Compact Multiband MIMO Antenna for Mobile Terminal

    Get PDF
    A novel compact MIMO antenna for personal digital assistant (PDA) and pad computer is proposed. The proposed antenna is composed by two multipatch monopole antennas which are placed 90° apart for orthogonal radiation. To strengthen the isolation, a T-shaped ground branch with proper dimension is used to generate an additional coupling path to lower the mutual coupling (below −15 dB), especially at GSM850/900 band. The proposed MIMO antenna is fabricated and tested, both the simulated and the measured results are presented, and some parametric studies are also demonstrated. In addition, there are some advantages about the proposed antenna such as simple structure, easy fabrication, and low cost

    Optimizing SVM’s parameters based on backtracking search optimization algorithm for gear fault diagnosis

    Get PDF
    The accuracy of a support vector machine (SVM) classifier is decided by the selection of optimal parameters for the SVM. The Backtracking Search Optimization Algorithm (BSA) is often applied to resolve the global optimization problem and adapted to optimize SVM parameters. In this research, a SVM parameter optimization method based on BSA (BSA-SVM) is proposed, and the BSA-SVM is applied to diagnose gear faults. Firstly, a gear vibration signal can be decomposed into several intrinsic scale components (ISCs) by means of the Local Characteristics-Scale Decomposition (LCD). Secondly, the MPE can extract the fault feature vectors from the first few ISCs. Thirdly, the fault feature vectors are taken as the input vectors of the BSA-SVM classifier. The analysis results of BSA-SVM classifier show that this method has higher accuracy than GA (Genetic Algorithm) or PSO (Particles Swarm Algorithm) algorithms combined with SVM. In short, the BSA-SVM based on the MPE-LCD is suitable to diagnose the state of health gear

    Direct three-dimensional imaging of polymer-water interfaces by nanoscale hard X-ray phase tomography

    Get PDF
    We report three-dimensional (3D) direct imaging of complex surface-liquid interfaces by hard X-ray phase contrast tomography as a non-destructive approach for the morphological characterization of surfaces at the micro- and nanoscale in contact with water. Specifically{,} we apply this method to study the solid-air-water interface in hydrophobic macroporous polymethacrylate surfaces{,} and the solid-oil-water interface in slippery liquid-infused porous surfaces (SLIPS). Varying the isotropic spatial resolution allows the 3D quantitative characterization of individual polymer globules{,} globular clusters (porosity) as well as the infused lubricant layer on SLIPS. Surface defects were resolved at the globular level. We show the first application of X-ray nanotomography to hydrated surface characterizations and we anticipate that X-ray nanoscale imaging will open new ways for various surface/interface studies

    Clustering-guided novel unsupervised domain adversarial network for partial transfer fault diagnosis of rotating machinery

    Get PDF
    Unsupervised partial transfer fault diagnosis studies of rotating machinery have practical significance, which still exists some challenges, for example, the learned domain-specific statistics and parameters usually influence the learning effect of target-domain features to some degree, and the relatively scattered target-domain features will lead to negative transfer. To overcome those limitations and further improve partial transfer fault diagnosis performance, a clustering-guided novel unsupervised domain adversarial network is proposed in this paper. Firstly, a novel unsupervised domain adversarial network is constructed using domain-specific batch normalization to remove domain-specific information to enhance alignment between source and target domains. Secondly, embedded clustering strategy is designed to learn tightly clustered target-domain features to suppress negative transfer in partial domain adaptation process. Finally, a joint optimization objective function is defined to balance different losses to improve the training and diagnosis performance. Two experimental cases of bevel gearbox and bearing are used to validate the effectiveness and superiority of the proposed method in solving unsupervised partial transfer fault diagnosis problems

    Geometric Filterless Photodetectors for Mid-infrared Spin Light

    Full text link
    Free-space circularly polarized light (CPL) detection, requiring polarizers and waveplates, has been well established, while such spatial degree of freedom is unfortunately absent in integrated on-chip optoelectronics. So far, those reported filterless CPL photodetectors suffer from the intrinsic small discrimination ratio, vulnerability to the non-CPL field components, and low responsivity. Here, we report a distinct paradigm of geometric photodetectors in mid-infrared exhibiting colossal discrimination ratio, close-to-perfect CPL-specific response, a zero-bias responsivity of 392 V/W at room temperature, and a detectivity of ellipticity down to 0.03o^o Hz−1/2^{-1/2}. Our approach employs plasmonic nanostructures array with judiciously designed symmetry, assisted by graphene ribbons to electrically read their near-field optical information. This geometry-empowered recipe for infrared photodetectors provides a robust, direct, strict, and high-quality solution to on-chip filterless CPL detection and unlocks new opportunities for integrated functional optoelectronic devices

    Tirofiban for Stroke without Large or Medium-Sized Vessel Occlusion

    Get PDF
    The effects of the glycoprotein IIb/IIIa receptor inhibitor tirofiban in patients with acute ischemic stroke but who have no evidence of complete occlusion of large or medium-sized vessels have not been extensively studied. In a multicenter trial in China, we enrolled patients with ischemic stroke without occlusion of large or medium-sized vessels and with a National Institutes of Health Stroke Scale score of 5 or more and at least one moderately to severely weak limb. Eligible patients had any of four clinical presentations: ineligible for thrombolysis or thrombectomy and within 24 hours after the patient was last known to be well; progression of stroke symptoms 24 to 96 hours after onset; early neurologic deterioration after thrombolysis; or thrombolysis with no improvement at 4 to 24 hours. Patients were assigned to receive intravenous tirofiban (plus oral placebo) or oral aspirin (100 mg per day, plus intravenous placebo) for 2 days; all patients then received oral aspirin until day 90. The primary efficacy end point was an excellent outcome, defined as a score of 0 or 1 on the modified Rankin scale (range, 0 [no symptoms] to 6 [death]) at 90 days. Secondary end points included functional independence at 90 days and a quality-of-life score. The primary safety end points were death and symptomatic intracranial hemorrhage. A total of 606 patients were assigned to the tirofiban group and 571 to the aspirin group. Most patients had small infarctions that were presumed to be atherosclerotic. The percentage of patients with a score of 0 or 1 on the modified Rankin scale at 90 days was 29.1% with tirofiban and 22.2% with aspirin (adjusted risk ratio, 1.26; 95% confidence interval, 1.04 to 1.53, P = 0.02). Results for secondary end points were generally not consistent with the results of the primary analysis. Mortality was similar in the two groups. The incidence of symptomatic intracranial hemorrhage was 1.0% in the tirofiban group and 0% in the aspirin group. In this trial involving heterogeneous groups of patients with stroke of recent onset or progression of stroke symptoms and nonoccluded large and medium-sized cerebral vessels, intravenous tirofiban was associated with a greater likelihood of an excellent outcome than low-dose aspirin. Incidences of intracranial hemorrhages were low but slightly higher with tirofiban

    A Fault Diagnosis Model Based on LCD-SVD-ANN-MIV and VPMCD for Rotating Machinery

    No full text
    The fault diagnosis process is essentially a class discrimination problem. However, traditional class discrimination methods such as SVM and ANN fail to capitalize the interactions among the feature variables. Variable predictive model-based class discrimination (VPMCD) can adequately use the interactions. But the feature extraction and selection will greatly affect the accuracy and stability of VPMCD classifier. Aiming at the nonstationary characteristics of vibration signal from rotating machinery with local fault, singular value decomposition (SVD) technique based local characteristic-scale decomposition (LCD) was developed to extract the feature variables. Subsequently, combining artificial neural net (ANN) and mean impact value (MIV), ANN-MIV as a kind of feature selection approach was proposed to select more suitable feature variables as input vector of VPMCD classifier. In the end of this paper, a novel fault diagnosis model based on LCD-SVD-ANN-MIV and VPMCD is proposed and proved by an experimental application for roller bearing fault diagnosis. The results show that the proposed method is effective and noise tolerant. And the comparative results demonstrate that the proposed method is superior to the other methods in diagnosis speed, diagnosis success rate, and diagnosis stability
    • …
    corecore